Introduction To and Background Of Sulphide Fires In Pillar Mining at the Sullivan Mine

CIM Bulletin, Vol. 70, No. 782, 1977
D. J. M. Farnsworth, Special Duties, Finance, Cominco Ltd., Vancouver, B.C.
Abstract Since the 1940's, the bulk of the ore production from the Sullivan Mine has come from pillars. These pillars, located from 100 to 2000 feet below surface, have been subjected to considerable ground pressure. Mining techniques were adopted to minimize the problems of deteriorating ground conditions. These techniques included an orderly sequential blasting of pillars along a retreat front, stage blasting of tall pillars in horizontal slices and utilization of broken pillars as "buffers". The latter two techniques involved leaving substantial tonnages of broken ore in place for as long as 4 years.
Rapid oxidation of metal sulphides, with attendant heat and noxious gas generation, had occurred in a few very localized areas of the mine associated with a major water course. However, in a very short period starting in 1972, sulphide fires spread to several of the large blocks of broken ore that had been left inactive for lengthy periods. There proved to be no feasible method of extinguishing these fires, except by complete removal of the burning ore. The attendant problems of handling large tonnages of burning ore have had considerable negative impact on the mine operation.
The chemical reactions involved in these sulphide fires have been studied by the mine staff to determine the conditions necessary for initiation and propagation of the fires. Techniques to safely and efficiently handle hot ore have been implemented and refined.
Lastly, and most important, mining methods at the Sullivan Mine have been revised to ensure that additional fires do not occur.
Keywords: Sullivan Mine, Sulphide fires, Pillar mining, Underground mining, Heated ore, Mine safety, Fires.
Full Access to Technical Paper